144
External interfaces
Com
GPI Out
ALARM Out
Example of GPI Out and ALARM connections
Ensure that the conditions given below are satisfied.
Dielectric strength: Max. DC 24 V
Current:
Max. 50 mA
AV-UHS500
(Max. voltage: 24 V)
Tally LED
(Max. current: 50 mA)
Com
GPI In
+3.3 V
Example of GPI In connections
Provide contact inputs.
AV-UHS500
TALLY/GPI 1
1
2
3
4
5
12
11
10
6
7
8
15
14
13
9
TALLY/GPI 2
1
2
3
4
5
12
11
10
6
7
8
15
14
13
9
Pin No.
Signal name
Pin No.
Signal name
1
GPI-Out1
1
GPI-Out10
9
GPI-Out9
9
GPI-Out18
2
GPI-Out2
2
GPI-Out11
10
ALARM Out
10
GPI-Out19
3
GPI-Out3
3
GPI-Out12
11
GPI-In1
11
GPI-In5
4
GPI-Out4
4
GPI-Out13
12
GPI-In2
12
GPI-In6
5
GPI-Out5
5
GPI-Out14
13
GPI-In3
13
GPI-In7
6
GPI-Out6
6
GPI-Out15
14
GPI-In4
14
GPI-In8
7
GPI-Out7
7
GPI-Out16
15
GPI-Com
15
GPI-Com
8
GPI-Out8
8
GPI-Out17
LAN
Connect the unit and computer or the unit and an external device
*.
*: An external device can be controlled from the unit.
p
p
Use a LAN cable (category 5e or above).