Aicure ANUP5255V2
Setting and UV irradiation by external devices
60
③
(When set in UV6)
Command
Response
At normal reception, the command message is returned as-is. However, “#” is changed to “$”.
■
Error code list
Error code
Error type
Control detail
20
Framing error
On the reception side, no high level was detected in the
timing when the stop bit should come.
It is because the clocks on the transmission side and on the
reception side were shifted in time or data was changed
during transmission.
21
Parity error
When the parity was valid, the parity check on reception
detected an error.
22
Overrun error
On reception, the CPU was late for readout of received
data.
23
Data immediate
error
This is because an error occurred immediately after data
transmission or reception.
40
Format error
The command transmission format is not correct. (Ex. “#” is
absent)
41
Command
Undefined error
This is because an undefined command not supported was
transmitted.
Header
Error message
symbol
Terminator
Address
Error code
Address
Start irradiation
intensity
Setting
pattern
「
6
」
Total irradiation
time
End irradiation
intensity
Same as the command.
Address
Summary of Contents for Aicure ANUP5255V2