DigitalFlow™ XMT868i Programming Manual
13
Chapter 1. Programming Site Data
1.3.3.7
Fluid Type (cont.)
1.3.3.8
Reynolds Correction
12.
Scroll to the appropriate choice to indicate whether you want
Reynolds Correction
.
• If
Off
is selected, enter the
Calibration Factor
and press
[Enter]
.
• If
Activ
is selected, the program asks for
KV Input Selection
. Scroll to
SIGS (Signals), SOUND (Soundspeed)
or
STATC.
•
If
SIGS
or
SOUND
is selected, enter the
Calibration Factor
and press
[Enter]
.
•
If
STATC
is selected, enter the
Kinematic Viscosity
and press
[Enter]
.
Then enter the
Calibration Factor
and
press
[
Enter].
•
For wetted transducers, the program returns to the
Channel PROGRAM
menu. You have completed entering
PIPE
parameters.
•
For clamp-on transducers, proceed to step 13 below.
1.3.3.9
Number of Traverses
13.
Scroll to the appropriate
Number of Traverses
(from 1 to 5) and press
[Enter]
.
14.
Accept the value for the
Transducer Spacing
by pressing
[Enter]
.
Note:
The XMT868i automatically calculates the transducer spacing. You should not enter a different value unless
specifically instructed by the factory
.
The XMT868i returns to the
Channel PROGRAM
menu. You have completed entering
PIPE
parameters.
Note:
The site data programmed in this chapter is automatically stored in the meter’s non-volatile RAM (NVR). If
the power to the meter is disconnected, the same site data will be applied when the unit is next powered on.
Table 9: Fluid Types for ENERGY ON
Tracking Windows =
NO
Additional Selections
YES
Additional Selections
Water
Enter the Water Temperature and press
[Enter].
Water,
0-260C
No additional selections required.
Water,
Glycol
Mixture
Enter the Fluid Soundspeed and press [Enter].
Then enter the Percentage of Water and press
[Enter].
Water,
Glycol
Mixture
Enter the Percentage of Water and press
[Enter].
OTHER
Enter the Fluid Soundspeed and press [Enter]. OTHER
Enter the Minimum Soundspeed and press
[Enter]. Then enter the Maximum Soundspeed
and press [Enter].
Summary of Contents for DigitalFlow XMT868i
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 50: ...Chapter 1 Programming Site Data 42 DigitalFlow XMT868i Programming Manual...
Page 74: ...Chapter 4 Printing Data 2 DigitalFlow XMT868i Programming Manual...
Page 78: ...Chapter 5 Clearing Data 4 DigitalFlow XMT868i Programming Manual...
Page 79: ...DigitalFlow XMT868i Programming Manual 5 Appendix A Menu Maps Appendix A Menu Maps...
Page 80: ...Appendix A Menu Maps 6 DigitalFlow XMT868i Programming Manual...
Page 86: ...Appendix A Menu Maps DigitalFlow XMT868i Programming Manual...
Page 144: ...Appendix D PanaView Menu Maps for the XMT868i 70 DigitalFlow XMT868i Programming Manual...
Page 150: ...Appendix A PanaView Menu Maps DigitalFlow XMT868i Programming Manual 76...
Page 162: ...Warranty 6 AquaTrans AT868 User s Manual no content intended for this page...
Page 163: ......