D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
116
The internal function setting data will be output below the JOB Nos. (registration Nos.)
T I P S
•
It is not possible to separately save the welding condition data recorded in memory and the
internal function setting data. Both of the data will always be written in the
"DAIHEN_OTC_WELDING_PARAMETER.CSV" file.
•
When importing the backup data to the welding power source, both or either of the data
above can be imported at one time.
"ALL": Welding condition data recorded in Internal function setting data
"1": Welding condition data recorded in memory
"2": Internal function setting data
7.3.2
Simplified data log function
The welding status can be checked on a computer by sampling the data during welding and backing them up in the USB
memory. Only three of the following data can be sampled. Adding to this, the "Heat input" will be displayed in column E.
The data types/sampling speed should be specified in the internal function F52/F53 (data log function).
(
6.7
-
Setting Internal Functions)
Simplified data log will be created below the "DAIHEN_OTC_Welbee\DAT\DAT00001" folder. A csv file will be created
per welding.
pls_bsi_adj
Base current fine
adjustment
1(A)
pre_uni_fset
Initial arc length adjustment
value
(when MS-MIG is selected)
0.1(±)
lpls_pki_adj
L pulse peak
current fine adjustment
1(A)
cre_uni_fset
Crater arc length
adjustment value
(when MS-MIG is selected)
0.1(±)
lpls_pkt_adj
L pulse peak
time fine adjustment
0.1 (ms)
Interval
Interval welding
0/1(OFF/ON)
lpls_bsi_adj
L base current
fine adjustment
1(A)
Interval_ON
Arc-ON time on interval
welding
0.01(s)
wave_feed_adj
Wave pulse
feed amplitude
1(%)
Interval_OFF
Arc-OFF time on interval
welding
0.01(s)
ctrl
Sequence information
(*1)
exp_ctrl
Extended control
information
−
wmode_H
Process information 1
(*2)
HiSpdPlsAdj
Adjustment value of pulse
auto-adjustment
−
wmode_L
Process information 2
(*2)
dummy1
〜
6
(reserved)
−
pre_feed
Initial feed speed
3.9 IPM
[0.1 m/min]
chksum
Checksum
Checksum
data
wld_feed
Welding feed speed
3.9 IPM
[0.1 m/min]
−
−
−
*1: Crater sequence and other information is recorded.
*2: Wire diameter, material, shield gas and other process information is recorded.
*3: Information of welding parameter table is recorded.
•
Welding current set value
•
Welding voltage set value
•
Wire feeding speed set value
•
Welding current actual value
•
Welding voltage actual value
•
Wire feeding speed actual value
Item
Description
Unit Item
Description
Unit
Function setting data