M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
64
6.5.2
Read out of welding conditions
This section explains how to read out the welding conditions registered in the memory.
T I P S
•
The current welding condition set on the operation panel is overwritten by the welding
conditions read out. To save the current welding condition, ensure to register it to the
memory.
1.
Display "LOAD JOB" in the MENU screen.
2.
Turn the screen operation knob (or parameter adjustment knob), and select the JOB No. to read out.
3.
Press the screen operation knob.
4.
Press the screen operation knob.
B
The welding condition is registered with the selected JOB No., and the read mode is terminated.
The selected position on the operation panel and the current/voltage values are overwritten to those read out.
●
Turn the screen operation knob and point the cursor to
LOAD JOB.
●
Press the screen operation knob.
B
The JOB No. (registration No.) is displayed on the right
digital meter in a flashing mode, and the LED of JOB lights
up.
B
On the left digital meter, the setting value of the welding
current registered to the JOB No. if any is displayed (if
there is no registration, "- - - -" is displayed), and the "A"
LED lights up.
B
If the welding condition corresponding to the selected JOB
No. is not registered, "no data" is displayed on the LCD
panel, and "- - - -" will flash on the left digital meter.
B
When there is no registration data on the selected JOB No.,
"no data" is displayed on the LCD panel and "- - - -" is
displayed on the left digital meter.
B
When there is any registration data on the selected JOB
No., the setting value of the welding current is displayed
on the left digital meter. At this time, the setting values of
crater or wire material also display on the LCD panel.
B
The setting values are displayed on the left/right digital
meters in a flashing mode.
B
Pressing the DISPLAY CHANGE key enables to check the
set values of welding conditions (welding parameters) to
read out. The setting values are displayed on the left/right
digital meters in a flashing mode.
•
To change the JOB No. to read out, pressing the CANCEL key to return
to the status described in step 1.
)81&7,216
/2$'-2%
6$9(-2%
:(/'021,725
.(</2&.㸸
%$&.83
0(18
2))
21
+20(
6(/(&7
(17(5