63
Chapter 6
W
elding Condition
M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
T I P S
•
Use of the internal function (F44) enables to read out the registered welding condition by the
analog remote control (optional). (
6.7
-
Setting Internal Functions)
•
Use of the internal function (F11) enables to finely adjust the current/voltage values read out
from the memory by the analog remote control (optional). (
6.7
-
Setting Internal
Functions)
6.5.1
Memory registration of welding conditions
This section explains how to register the current welding condition set on the operation panel to the memory.
1.
Display "SAVE JOB" in the MENU screen.
2.
Turn the screen operation knob (or parameter adjustment knob), and select a JOB No.
3.
Press the screen operation knob.
4.
Press the screen operation knob.
B
The welding condition is registered with the selected JOB No., and the storage function mode is terminated.
The registered welding condition can be read out for use.
●
Turn the screen operation knob and point the cursor to
SAVE JOB.
●
Press the screen operation knob.
B
The JOB No. (registration No.) is displayed on the right
digital meter in a flashing mode, and the LED of JOB lights
up.
B
On the left digital meter, the setting value of the welding
current registered to the JOB No. if any is displayed (if
there is no registration, "- - - -" is displayed), and the "A"
LED lights up.
B
If the welding condition corresponding to the selected JOB
No. is not registered, "no data" is displayed on the LCD
panel, and "- - - -" will flash on the left digital meter.
B
When there is no registration data on the selected JOB No,
"no data" is displayed on the LCD panel, and "- - - -" is
displayed on the left digital meter.
B
When there is a registration data on the selected JOB No.,
the set welding current value is displayed on the left
digital meter.
B
"- - - -" is displayed on the left and right digital meters in a
flashing mode.
•
To cancel the memory registration, press the CANCEL key. The "SAVE
JOB" mode is terminated.
)81&7,216
/2$'-2%
6$9(-2%
:(/'021,725
.(</2&.㸸
%$&.83
0(18
2))
㸭21
+20(
6(/(&7
(17(5