D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
120
7.3.6
Importing backup data
This section explains how to import the backup data.
NOTE
•
The data stored in the welding power source will be overwritten by the backup data. Make
sure of it before overwriting.
1.
Turn ON the power switch.
2.
Insert the USB flash drive to the USB connector of the operation panel.
3.
Display "RESTORE" in the MENU screen.
4.
Select the data to import.
5.
Press the screen operation knob.
●
Turn the screen operation knob to place the cursor on
"RESTORE", and press the knob.
B
"ALL" or JOB No. (registration No.) is displayed on the
right digital meter in a flashing mode, and the LED of
"JOB" lights up.
B
"USb" is displayed on the left digital meter.
●
Turn the parameter adjusting knob further
counterclockwise to display the data to import on the right
digital meter.
B
The display changes in order of "ALL" -> "1" -> "2".
•
"ALL" means that all the data ("1" to "2") available for importing are
selected.
•
Details of the numbers displayed (
7.3
-
Data Backup (Utilization of
data))
B
Flashing of the left/right digital meter displays will stop,
and the display changes to the light-up mode.
/2$'-2%
6$9(-2%
:(/'021,725
.(</2&.㸸
%$&.83
5(6725(
0(18
2))
㸭21
+20(
6(/(&7
(17(5