2.
Select the desired monitor No.
3.
Turn the screen operation knob (or parameter adjustment knob), and change the setting value.
4.
Press the CANCEL key.
B
The screen will return to the MENU screen.
B
When the set target is achieved or at the time of WARNING detection, an alarm will appear on the left/right
digital meters. (
7.2.2
-
Details of welding control items)
7.2.2
Details of welding control items
This section explains about details of the welding control items.
7.2.2.1
Number of welding point
The number of welding points is controlled according to the setting range.
•
P10 (Cumulative number of welding points)
The interval from the start of current flowing triggered by the torch switch ON to the stop of output triggered by the
torch switch OFF is regarded as one count (one welding point) and accumulated.
The setting range of count value is between 0 and 9999. The count value will be cleared according to the "P12" setting.
(If continuous operation is enabled, the value will be cleared when exceeding 9999 and return to 0.)
•
P11 (Target value of welding points)
Select the target value of welding points in the range from 0 to 9999. When the "P10" count value reaches the number
of welding points specified here, an alarm appears indicating that the target is achieved. (
7.2.2.6
-
Alarm indication
when target is achieved)
•
P12 (Operation at the time when the target value of welding points is achieved)
Select the operation from 0 to 5 for the time when the target specified for "P11" is achieved. The set values and
operations when the target is achieved are as below.
●
Turning the screen operation knob (or parameter
adjustment knob) will change the tens place digit of
monitor No. (Example: "P10" -> "P20" -> "P30" -> "P40")
●
Pressing the screen operation knob will change the ones
place digit of monitor No. (Example: "P10" -> "P11" ->
"P12")
B
When an appropriate monitor No. is selected on the left
digital meter, the right digital meter will flash.
B
The set value is displayed on the right digital meter.
B
To select another monitor No., press the screen operation
knob until the ones place digit is set at "0" on the digital
meter, and perform the same operation as step 2
Operation
Set value
0
1
2
3
4
5
The count value is cleared when the target is achieved (*1)
Yes
No
Yes
No
No
No
Operation is continued after the target is achieved (*2)
Enable
Enable
Enable
Enable
Disabled
Disabled
The count value is cleared when the power is turned on
Yes
Yes
No
No
Yes
No
*1: When an alarm is displayed, pressing any key of the operation panel can also clear the count value.