7.3.1
Setting of welding conditions/internal functions
The following contents can be stored in the "DAIHEN_OTC_WELDING_PRAMETER.CSV" file.
•
All the welding condition data recorded in memory
•
The internal function values at the time of data backup
The current welding conditions set with the operation panel will not be saved. (If necessary, record them in memory
beforehand.)
The welding condition data recorded in the memory will be output in the way that the JOB Nos. (registration Nos.) are
displayed in a vertical line and the parameter values in a horizontally line.
Item
Description
Unit Item
Description
Unit
job_num
JOB No.
-255
〜
-155,
1
〜
100
cre_feed
Crater feed speed
3.9 IPM
(0.1 m/min)
spot_tim
Arc Spot
time
0.1(s)
ant_tim_adj
Anti-stick time adjustment
0.01(s)
prf_tim
Pre-flow time
0.1(s)
ant_vset_adj
Anti-stick voltage
adjustment
0.1(V)
pre_iset
Initial current
1(A)
sldwn_adj
Slowdown adjustment
3.9 IPM
[0.1 m/min]
pre_vset
Initial voltage
0.1(V)
up_slp_tim
Up-slope
time
0.1(s)
pre_uni_vset
Initial voltage (synergic)
1(±)
dwn_slp_tim
Down-slope
time
0.1(s)
wld_iset
Welding current
1(A)
pre_tim
Initial time
0.1(s)
wld_vset
Welding voltage
0.1(V)
cre_tim
Crater time
0.1(s)
wld_uni_vset
Welding voltage (synergic)
1(±)
KubireAutoAdj
Automatic correction of
[squeeze]
0/1(OFF/ON)
cre_iset
Crater current
1(A)
KubireAutoSave
Saving [squeeze]
−
cre_vset
Crater voltage
0.1(V)
KubireP1P
Spatter control P1P
1(±)
cre_uni_vset
Crater voltage
(synergic)
1(±)
KubireP2P
Spatter control P2P
1(±)
aff_tim
Post-flow time
0.1(s)
PerIset
Current value change
setting
0/1(OFF/ON)
arc_char
Arc characteristics
1(±)
PreIsetPer
Current value setting (initial
conditions)
1(%)
wave_frq
Wave frequency
0.1(Hz)
CreIsetPer
Current setting (crater fill)
1(%)
arc_char2
Arc characteristics
(reserved)
−
TsCrickIset
Torch switch
current adjustment
0/1(OFF/ON)
pre_sens_slp
[Squeeze] detection
sensitivity (reserved)
−
CriIsetStep1
Single click adjustment
value
1(A)
pre_sens_cnst
−
−
CriIsetStep2
Double click
adjustment value
1(A)
pls_pki_adj
Pulse peak current
fine adjustment
1(A)
WModeTblNo
Welding table No.
(
*3
)
pls_pkt_adj
Pulse peak time
fine adjustment
0.1 (ms)
wld_uni_fset
Arc length adjustment value
(when MS-MIG is selected)
0.1(±)
"-" is shown for unused condition numbers.
Parameter of condition No.1
Parameter value
JOB No.