S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
102
6.7.2.59 F85: Adjustment amount of pulse automatic adjustment
The currently retained adjustment amount of pulse automatic adjustment can be checked. In addition, the adjustment
amount can be changed manually.
•
Setting range of the value: -9.99 to 9.99.
T I P S
The adjustment amount is set in a way that the appropriate welding is possible when the value
is "0". However, factors such as welding environment (base metal side / torch side cable, torch
cable length and routing) and welding work conditions (posture, welding conditions such as lap
and fillet, and wire extension) leads to fluctuation of the appropriate adjustment amount from
zero.
Even if the adjustment amount is changed manually, the amount will be updated when welding
is carried out after internal function F84 (Pulse automatic adjustment) is set at "1".
6.7.2.60 86/F87: Current display adjustment (GAIN/OFFSET)
Set the adjustment value (gain/offset) when the current display value on the left digital meter is different from the actual
current value.
The current value displayed on the digital meter is obtained by software processing of the average value of outputs;
therefore, it may not be consistent with the value indicated on a needle meter, etc. When this happens, using this function
enables to finely adjust the current display value.
•
For F86, set gain, and for F87, set offset.
Changing the set value only corrects the display; the output welding current does not change.
•
For more information on the adjustment procedure, contact dealer.
NOTE
•
Do not carelessly change the setting of this function.
6.7.2.61 F88/F89: Voltage display adjustment (GAIN/OFFSET)
Set the adjustment value (gain/offset) when the voltage display value on the right digital meter is different from the actual
voltage value.
The voltage value displayed on the digital meter is obtained by software processing of the average value of outputs;
therefore, it may not be consistent with the value indicated on a needle meter, etc. When this happens, using this function
enables to finely adjust the voltage display value.
•
For F88, set gain, and for F89, set offset.
Changing the set value only corrects the display; the output welding voltage does not change.
•
For more information on the adjustment procedure, contact dealer.
NOTE
•
Do not carelessly change the setting of this function.