Setting of current value (crater
condition)
10 to 300
100 (%)
Sets the current value of the crater condition in the
percentage based on the current value of the welding
condition.
㾎
F70
Setting of upper limit of analog
remote control
20 to 400
400 (A)
Sets the upper limit (the value when the knob is turned
clockwise all the way) of the welding current adjustable
by the analog remote control (optional accessory).
-
F71
Interval welding function
OFF/ON
OFF
This function repeats arc ON/OFF to control the heat
input.
㾎
F72
Setting Arc-ON time
(Interval function)
0.20 to 9.99
1.00 (s)
Sets the arc-ON time in the Interval welding function.
㾎
F73
Setting Arc-OFF time
(Interval function)
0.20 to 9.99
1.00 (s)
Sets the arc-OFF time in the Interval welding
㾎
F74 to
F76
No function
OFF (fixed)
OFF
No functions are provided.
-
F77
Welding source identification
numbers
1 to 999
1
Sets whether power source identification numbers of
Welding result control function.
-
F78
Prevention of unintended torch
switch operation
OFF/ON
OFF
An error code is displayed when welding is not
performed for five seconds after the pre-flow.
-
F79
Switching of CAN
communication connection
device
0/1/2/3
0
Sets the connection device to be used for the CAN
communication.
0: Digital Remote Control Box
1: Digital panel (Attached to wire feeder) and intelli torch
2: Push-Pull torch
3: Inline Assist feeder
-
F80
Switching of CAN
communication speed
0/1/2/3
0
Sets the connection speed of the CAN connection.
0: 500kbps
1: 1Mbps
2: 125kbps
3: 250kbps
-
F81
TIG Mode switch setting
OFF/ON
OFF
During TIG MODE, operating the torch switch can control
the welding start and end.
-
F82
Extended correction for
DC Pulse welding
0 to 30
0
If DC pulse welding is done with the output cable
extended, welding may become unstable. Adjustment of
this parameter may stabilize the welding.
-
F83
Arc length adjustment right after
starting
-20 to 10
0
Adjusts the arc length right after starting the welding
operation.
-
F84
Pulse automatic adjustment
0/1/2
0
Sets the pulse mode that has the pulse automatic
adjustment function.
0: Standard pulse mode
1: Pulse mode for automatic adjustment
2: Pulse mode for automatic adjustment; Fixing of
adjustment value
㾎
F85
Adjustment amount of pulse
automatic adjustment
-9.99 to 9.99
0
The currently retained adjustment amount of pulse
automatic adjustment can be checked. In addition, the
adjustment amount can be changed manually.
㾎
F86
Current display adjustment
(GAIN)
-20 to 20
0 (%)
These functions are for adjusting current value
displayed on the digital meter.
-
F87
Current display adjustment
(OFFSET)
-20 to 20
0 (A)
F88
Voltage display adjustment
(GAIN)
-20 to 20
0 (%)
These functions are for adjusting voltage value
displayed on the digital meter.
-
F89
Voltage display adjustment
(OFFSET)
-2.0 to 2.0
0.0 (V)
No.
Function Name
Setting range
Initial value
Explanation
Memory