MAINTENANCE
15.4 Replacement of exhaust filter
1)
To reach the pump, follow the procedure explained from points 3 to 6
under “Replacement of pump oil”.
2)
Unscrew the exhaust filter cap located on the body of the pump using
pliers. Remove the exhaust filter
(Fig. 16-17)
.
3)
Position the new filter with the O-ring and use the pliers to screw on the
new cap supplied with the filter.
4)
Close the appliance again following the procedure explained from points
11 to 12 under “Replacement of pump oil”.