For almanac data:
http://[IP address of your unit]/files/pub/gps/data/almanac/[YYYY]/[ZZZ]/[ZZZ].alm
Where:
YYYY
: Year (Example: "2017"), and
ZZZ
: Day of year (Example: "050" for 19-
February)
3.3.4
Holdover Mode
When input references have been supplying input to VelaSync and input from all the ref-
erences has been lost, VelaSync will not immediately declare loss of time synchronization,
but first will go into Holdover mode. While the unit is in Holdover mode, the time outputs
are derived from the internal 10 MHz oscillator incrementing the System Time, but the
oscillator is not disciplined/steered by the external reference e.g., GNSS.
Because of the stability of the internal oscillator, accurate time can still be derived even
after all the primary references are no longer valid or present. The more stable the oscil-
lator is without an external reference, the longer this holdover period can be and have it
still maintain very accurate outputs. The benefit of Holdover is that time synchronization
and the availability of the time outputs is not immediately lost when input references are
no longer available.
While VelaSync is in Holdover, the only difference is the Holdover and associated Minor
alarm are asserted. There are no changes to NTP or any of the other outputs, i.e. while in
Holdover mode, NTP inside VelaSync continues to be at the same Stratum level it was at
before going into Holdover mode (such as Stratum 1 when synced to GPS). Should the Hol-
dover period expire, however, or the unit is rebooted, the NTP Stratum will go to 16, pre-
venting any clients from being able to sync with VelaSync until GPS or another reference
has been restored.
How long will the unit remain in Holdover mode?
148
CHAPTER
3
•
VelaSync 1232 User Manual Rev. 4
3.3 Managing References
Summary of Contents for Spectracom VelaSync 1232
Page 2: ......
Page 4: ...Blank page II VelaSync 1232 User Manual...
Page 12: ...BLANK PAGE X VelaSync 1232 User Manual TABLE OF CONTENTS...
Page 28: ...16 CHAPTER 1 VelaSync 1232 User Manual Rev 4 1 7 The VelaSync Web UI...
Page 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync 1232 User Manual Rev 4...