Note that all IRIG outputs has its own available ‘offset’ capability, which is configurable via
VelaSync’s Web UI, to help account for cabling and processing delays of the device each
output is connected with.
5.3.2
IRIG Carrier Frequencies
Each IRIG code specifies a carrier frequency that is modulated to encode date and time, as
well as control bits to time-stamp events. Initially, IRIG applications were primarily military
and government associated. Today, IRIG is commonly used to synchronize voice loggers,
recall recorders, and sequential event loggers found in emergency dispatch centers and
power utilities.
Table 5-3:
Available IRIG output signals
Format
Encoding Modulation
Carrier
Coded Expressions
Bit rate
Time Frame
Interval
IRIG-A
IRIG-A
A000
DCLS
N/A
BCD
TOY
, CF and SBS
1000
pps
0.1 sec
IRIG-A
A001
DCLS
N/A
BCD
TOY
, CF
1000
pps
0.1 sec
IRIG-A
A002
DCLS
N/A
BCD
TOY
1000
pps
0.1 sec
IRIG-A
A003
DCLS
N/A
BCD
TOY
, SBS
1000
pps
0.1 sec
IRIG-A
A004
DCLS
N/A
BCD
TOY
, BCD
YEAR
, CF
and SBS
1000
pps
0.1 sec
IRIG-A
A005
DCLS
N/A
BCD
TOY
, BCD
YEAR
, and
CF
1000
pps
0.1 sec
IRIG-A
A006
DCLS
N/A
BCD
TOY
, BCD
YEAR
1000
pps
0.1 sec
IRIG-A
A007
DCLS
N/A
BCD
TOY
, BCD
YEAR
, and
SBS
1000
pps
0.1 sec
IRIG-A
A130
AM
10 kHz
BCD
TOY
, CF and SBS
1000
pps
0.1 sec
IRIG-A
A131
AM
10 kHz
BCD
TOY
, CF
1000
pps
0.1 sec
IRIG-A
A132
AM
10 kHz
BCD
TOY
1000
pps
0.1 sec
VelaSync 1232 User Manual
221
APPENDIX
Summary of Contents for Spectracom VelaSync 1232
Page 2: ......
Page 4: ...Blank page II VelaSync 1232 User Manual...
Page 12: ...BLANK PAGE X VelaSync 1232 User Manual TABLE OF CONTENTS...
Page 28: ...16 CHAPTER 1 VelaSync 1232 User Manual Rev 4 1 7 The VelaSync Web UI...
Page 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync 1232 User Manual Rev 4...