4.2
Rebooting the System
To reboot VelaSync via the Web UI:
1.
Navigate to
TOOLS > SYSTEM: Reboot/Halt
.
2.
Select the
Restart after Shutdown
box in the
Reboot/Halt
window.
3.
VelaSync will now be rebooted and be accessible again shortly thereafter.
Rebooting via USB Port, Telnet, SSH, SNMP
With a serial connection to the USB port, telnet connection or SSH connection, type
reboot
<Enter> to reboot VelaSync.
Reboot is also is available to be performed through an
snmpset
operation. For more
information on VelaSync commands, see
4.3
Hardware Tasks
4.3.1
Replacing a Power Supply
For redundancy purposes, the server is equipped with two hot-swap power supply mod-
ules. Should either of the modules fail, the other will take the full load, and supply power
without interruption to the server.
Since the power supplies can be hot-swapped, the VelaSync unit does not have to be shut
down, in order to replace the defective power supply.
Caution:
Allow the power supply modules to cool before touching.
1.
To determine which of the two power supplies failed, on the back side of the server
check the LED located on either power supply. The LED of a failed power supply will
not light up.
2.
Unplug the power cord of the defective power supply.
4.2 Rebooting the System
CHAPTER
4
•
VelaSync 1232 User Manual Rev. 4
163
Summary of Contents for Spectracom VelaSync 1232
Page 2: ......
Page 4: ...Blank page II VelaSync 1232 User Manual...
Page 12: ...BLANK PAGE X VelaSync 1232 User Manual TABLE OF CONTENTS...
Page 28: ...16 CHAPTER 1 VelaSync 1232 User Manual Rev 4 1 7 The VelaSync Web UI...
Page 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync 1232 User Manual Rev 4...