background image

Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions

– Read and Save These Instructions –

This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can 

proceed successfully. Ultimate satisfaction depends on the quality of installation and a thorough understanding of 

this equipment. The dehumidifier is built around tested engineering principles and has passed a thorough inspection 

for quality of workmanship and function.

TS-1040 

01/18 Rev. C

1

4201 Lien Rd 

Madison, WI 53704 

Toll-Free 1-877-420-1330

www.QuestHydro.com [email protected] 

Specifications subject to change without notice.

Quest Dry

50Hz Quest CDG 114

50Hz Quest CDG 114:

•  Energy Efficiency- 

Removes 55 pints at AHAM while 

drawing only 3. amps

•  Slide out handle
•  Internal pump
•  MERV-11 pleated filter
•  Onboard control panel

Water Removal Rates Per Day @ 26.7°C (80°F) 60% (AHAM)

 

 

Dehumidifier  Liters Pints/Gallons

 

Quest CDG 114 

55 

114/14.5

Summary of Contents for CDG 114

Page 1: ...difier is built around tested engineering principles and has passed a thorough inspection for quality of workmanship and function TS 1040 01 18 Rev C 1 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestHydro com info QuestHydro com Specifications subject to change without notice Quest Dry 50HzQuestCDG114 50Hz Quest CDG 114 Energy Efficiency Removes 55 pints at AHAM while drawing only...

Page 2: ...uirements 5 2 3 Condensate Removal 5 2 4 Ducting 5 2 5 Defrost Cycle 5 2 6 Power Button 5 2 7 Purge Button 6 2 8 Hour Meter 6 2 9 Hours Button 6 2 10 Defrost Light 6 2 11 Bypass Cover 6 3 Maintenance 7 3 1 Air Filter 7 3 2 Storage and Freeze Protection 7 4 Service 7 4 1 Technical Description 8 4 2 Troubleshooting 8 4 3 Air Mover 10 4 4 Thermistor 10 4 5 Condensate Pump 11 4 6 Float Safety Switch 1...

Page 3: ...RUPTER outlet reduces the risk of shock or fire Never operate a unit with a damaged power cord If the power cord is damaged it must be replaced with a cord of the same type amperage rating and have the appropriate country specific grounded plug Extension cords must be grounded and able to deliver the appropriate voltage Always operate the unit on a stable and level surface Do not use the unit as a...

Page 4: ...euverability and roll over obstacles with ease The telescoping handle and recessed wheels create a compact dehumidifier for improved storage and transport To operate the telescoping handle pull out the lever to release the lock and lift the handle until it locks in the up position Repeat to lock the handle in the down position More compact storage can be achieved by stacking 4035540 XX Quest CDG 1...

Page 5: ...nsate level rises in the reservoir to a critical level a back up float switch will activate the pump out for up to 1 minute If the water in the reservoir fails to be evacuated the safety switch will turn off the compressor 2 4 Ducting A wire duct collar is supplied to allow 25cm lay flat duct to be attached to the Quest CDG 114 outlet Attach ducting to the wire duct collar by inserting the plastic...

Page 6: ...d next time the unit is powered on 2 9 HOURS Button Pressing the HOURS button displays the hour meter when the unit is turned off but plugged into power To reset job hours press and hold the HOURS button for 5 seconds when the unit is operating 2 10 Defrost Light The DEFROST light turns on when the unit is in defrost cycle and indicates when the compressor is off 2 11 Bypass Cover Below 32ºC When ...

Page 7: ...cautions are taken to remove as much as possible before storage 1 Use the pump PURGE button to reduce the water level in the reservoir 2 Stretch the hose flat to drain it completely Raise one end above your head and spool hose while draining water out the other end 3 To reduce biological growth flush the unit with a bio fungicide that is approved for use with copper aluminum and polyethylene To fl...

Page 8: ...n constant pressure and temperature across the entire coil from inlet to outlet The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil The accumulator prevents any liquid refrigerant from reaching the compressor The compressor evacuates the cool refrigerant gas from the accumulator and compresses it to a high pressure and temperature to repeat the process...

Page 9: ... connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defective defrost thermistor 6 Low refrigerant charge 7 Air leak such as loose cover 8 Def...

Page 10: ...r and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the four screws attaching the bottom plate to the lower housing 3 Disconnect the impeller leads 4 Remove the four screws holding the impeller to the bottom plate 5 Reassemble the new impeller using the above procedure in reverse 4 4 Thermistor The defrost thermistor is attach...

Page 11: ... 6 Float Safety Switch The float safety switch activates when the water rises too high in the condensate reservoir The float safety switch turns off the compressor until the water level lowers and disengages the switch To replace the float safety switch 1 Unplug the dehumidifier 2 Remove the front housing 3 Unplug the float safety switch wires from the wire harness 4 Remove the one screw attaching...

Page 12: ...o QuestHydro com BLU 14 RED 13 COMPRESSOR BLOWER MOTOR LEVEL SWITCH CONTROL BOARD THERMISTOR CONDENSATE PUMP WHT 10 GRN BLK WHT 2 YEL 9 YEL 8 RUN CAPACITOR RUN CAPACITOR BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 3 Electrical schematic of Quest CDG 114 5 Wiring Diagram ...

Page 13: ...tion Qty Part No Filter 30cm x 30cm x 2 5cm 1 4025568 Hose 1 4 ID x 10m long 1 4024916 Control Board 1 4028255 Capacitor Compressor 30 μF 1 4033032 02 Capacitor Impeller 4 μF 1 4035235 01 Compressor 1 4028251 Evaporator Coil 1 4034472 05 Condenser Coil 1 4028235 02 Condensate Pump 1 4034582 02 Float Safety Switch 1 4034374 Impeller Air Mover 1 4028254 ...

Page 14: ...means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Quest CDG 114 Dehumidifier part is r...

Page 15: ...es responsable por el cuidado normal Esta garantía no cubre cualquier defecto avería etc que resulte del uso indebido abuso falta de cuidado normal corrosión congelación manipulación modificación reparación o instalación no autorizada o indebida accidentes eventos naturales o cualquier otra causa más allá del control razonable de Therma Stor LLC LIMITACIONES Y EXENCIONES Si cualquier parte del des...

Page 16: ...tro 30cm x 30cm x 2 5cm 1 4025568 Manguera ID 1 4 x 10m de largo 1 4024916 Tablero de control 1 4028255 Condensador compresor 30 μF 1 4033032 02 Condensador propulsor 4 μF 1 4035235 01 Compresor 1 4028251 Bobina del evaporador 1 4034472 05 Bobina del condensador 1 4028235 02 Bomba de condensados 1 4034582 02 Interruptor de seguridad flotante 1 4034374 Propulsor motor de aire 1 4028254 ...

Page 17: ...ables del interruptor de seguridad flotante del arnés de cables 4 Remueva el tornillo que ajusta la horquilla de la bomba y el interruptor de seguridad flotante al soporte del compresor 5 Remueva la bomba de la reserva y deslice hacia afuera el interruptor flotante desde debajo del soporte del compresor 6 Reemplace el flotante bomba cableado tornillos y carcasa en orden inverso BLU 14 RED 13 COMPR...

Page 18: ...emplazar el termistor 1 Desconecte el deshumidificador 2 Remueva la carcasa frontal 3 Corte los sujetacables y remueva la cinta aislante de aluminio 4 Remueva el panel de control 5 Desenrosque el termistor del ojal de la carcasa de control 6 Desprenda el termistor del puente del panel de control 7 Rearme el termistor y el deshumidificador utilizando el procedimiento previo a la inversa 4 5 Bomba d...

Page 19: ...ectada 2 Motor de la bomba defectuoso 3 Válvula de comprobación de la bomba conectada 4 Mala conexión en el circuito de la bomba 5 Manguera desconectada internamente 6 Panel de control defectuoso fase de bombeo La unidad bombea agua de forma automática pero no cuando se presiona el botón PURGE 1 Mala conexión en el circuito del botón PURGE 2 Panel de control defectuoso La bobina del evaporador se ...

Page 20: ...d está en modo de descongelación la luz DEFROST está encendida 2 El termistor de descongelación está defectuoso o flojo 3 Conexión floja en el circuito del compresor 4 Sobrecarga en el compresor defectuoso 5 Compresor defectuoso 6 Relé defectuoso 7 La carcasa superior no está sellada a la carcasa inferior No funciona la deshumidificación el aire se mueve pero el compresor no 1 Mala conexión en el ...

Page 21: ...ar la carcasa delantera 4 1 Descripción técnica El Quest CDG 114 utiliza un sistema de refrigeración similar a un aire acondicionado para remover el calor y la humedad del aire entrante y para añadir calor al aire despedido Gas refrigerante caliente y de alta presión se envía desde el compresor a la bobina condensadora El refrigerante se enfría y condensa transmitiendo su calor al aire que está a ...

Page 22: ...1 Utilizar la unidad con un filtro sucio reduce la capacidad y eficiencia del deshumidificador y puede forzar la unidad a descongelarse causando que el compresor varíe entre apagado y encendido de forma innecesaria El filtro generalmente puede ser aspirado antes de necesitar un reemplazo Los filtros de repuesto pueden ser encargados al fabricante o comprados de forma local si están disponibles IMP...

Page 23: ...o apagado y la bomba funcionará durante 30 segundos Siempre elimine manualmente el agua de la reserva antes de transportar o almacenar Apague la unidad y permita que el deshumidificador enchufado repose 15 minutos antes de la eliminación final 2 8 Contador horario El contador horario digital muestra la cantidad de tiempo que el deshumidificador ha estado encendido hasta el décimo de una hora El co...

Page 24: ...ipado con una bomba de condensados interna para remover el agua que es condensada durante la deshumidificación Esta bomba permite que el condensado sea bombeado 4m sobre la unidad por la manguera conectada Si el condensado debe bombearse a más de 4m sobre la unidad una bomba de relevo debe añadirse La bomba de condensados depura de forma automática por 20 segundos cada ocho minutos Utilice el botó...

Page 25: ...e las temperaturas de 21 C y 35 C Quest CDG 114 4035540 XX Voltaje de entrada 220 240 VAC 1 Fase 50 Hz Consumo de corriente amperes 3 7 Temperatura operacional Mínimo 1 C 33 F Máximo 40 C 110 F Remoción de agua litros día Eficiencia litros kWh 55 2 8 Filtro de aire MERV 11 Tamaño 30 cm x 30 cm x 3 cm Tipo de refrigerante Cantidad de refrigerante R410A 1lb 10oz Opciones de tubería Salida Plana de 2...

Page 26: ...que reduce el riesgo de descarga o incendio Nunca utilice una unidad con el cable de alimentación dañado Si el cable eléctrico está dañado debe reemplazarse con un cable del mismo tipo y amperaje y tener el toma corrientes apropiado para el país específico Los cables de extensión deben ser a tierra y ser capaces de brindar el voltaje apropiado Utilice siempre la unidad en una superficie estable y ...

Page 27: ...Ciclo de descongelación 5 2 6 Botón de encendido 6 2 7 Botón de depuración 6 2 8 Contador horario 6 2 9 Botón horario 6 2 10 Luz de descongelación 6 2 11 Cubierta de circunvalación 7 3 Mantenimiento 7 3 1 Filtro de aire 7 3 2 Almacenamiento y protección contra congelación 7 4 Inspección 8 4 1 Descripción técnica 8 4 2 Solución de problemas 9 4 3 Movimiento de aire 11 4 4 Termistor 11 4 5 Bomba de ...

Page 28: ...rios de ingeniería probados y ha pasado por una inspección de calidad de fabricación y funcionamiento TS 1040 Modificación C el 01 18 1 4201 Lien Rd Madison WI 53704 Línea gratuita 1 877 420 1330 www QuestHydro com info QuestHydro com Las especificaciones pueden cambiar sin previo aviso Quest Dry Quest CDG 114 DE 50Hz Quest CDG 114 de 50Hz Eficiencia energética Remueve 55 pintas a AHAM mientras co...