n
Set Year
: To set the current year, use “F3” and “F4” to select the current year. Press “Enter” to
save and exit, or “Clear” to undo changes and exit.
Keyboard and Reader
: The Keyboard and Reader item, when selected, displays the following keyboard-
related configuration items:
l
Prompt Time-Out
: Determine the amount of time that prompts show until they go out of view.
l
Error Message Time-Out
: Determine the amount of time that error messages show until they go out
of view.
l
Second Card Time-Out
: Used for the second card in Dual Card transactions. The default for the card
reader timeout value is 15 seconds.
Manager Cards
: The Manager Cards item displays the following card-related configuration items:
l
Reset Card 1
: Manager card 1 can be reconfigured.
l
Reset Card 2
: Manager card 2 can be reconfigured.
l
Force Manager PIN
: Ensures that if a proprietary card PIN is disabled (PCF), a manager card can
always be forced to enter PIN. This is a security measure to protect
Manager Mode
entry.
l
Lock Reset
: A manager can re-configure the manager menu PIN in the event that the second
Manager Card needs to be locked out for security reasons.
Site Options
: This option displays the current purchased system options, SIMM serial number, and
Electronic Serial Number (ESN). Also use this option to update purchased options through the USB door key.
l
Insert a USB key with options (purchased separately) in the USB door port and press the “Update”
function key.
NOTE:
The Number of Cards and Number of Pumps fields on the Site Options screen can
show up to four (4) pumps.
CLOSE /OPEN Site now
: This option immediately changes the state of the system.
Site Operation when USB not present
: This option can be used to control whether the site will shutdown
if the internal USB key is not available to record transactions.
Doc. No.: M1900 Rev.: 8
Page 39 of 65