4-26
Section 4
CONNECTING TO EXTERNAL DEVICES
ZUV
User’s Manual
Section 4
Connection by USB/RS-232C
DATAGET command
This command obtains the irradiation conditions of the respective channel.
(1)
Parameter description
The following parameters can be set and obtained by the DATAGET command:
(2)
Command/response examples
The following shows an example of this command:
The following shows an example of a response to this command. Each line is separated by a
delimiter.
DATAGET <Channel No.> <Parameter No.>
<Obtained data>
OK
Parameter
Setting Range/Output Range
Channel No.
0: Channel 1
1: Channel 2
2: Channel 3
3: Channel 4
Parameter No.
32: Irradiation mode
33: Irradiation power
34: Irradiation time
35: Irradiation pattern
38: Irradiation time and type
Obtained data
When the irradiation mode is set:
0: OFF
1: CONSTANT
2: PATTERN
When the irradiation power is set:
0 to 100
When the irradiation time is set:
0 to 9999 (*0.1s)
When the irradiation pattern is set:
0 to 15 (Actual pattern No. - 1)
When the irradiation time type is set: 0: SETTING
1: UNLIMITED
DATAGET 0 32
←
The irradiation mode of channel 1 is
obtained.
DATAGET 1 35
←
The irradiation pattern of channel 2 is
obtained.
1
←
Constant irradiation is set to channel 1.
OK
15
←
Pattern 16 is set to channel 2.
OK
Command
Delimiter
Delimiter
Response
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Delimiter
Summary of Contents for ZUV Series
Page 1: ...Smart Curing System User s Manual Cat No Z281 E1 02 ZUV Series Mega Power Type...
Page 18: ...16 ZUV User s manual CONTENTS Introduction CONTENTS MEMO...
Page 44: ...2 18 Section 2 ZUV BASIC OPERATION ZUV User s Manual Section 2 Operating Modes MEMO...
Page 68: ...3 24 Section 3 SETUP ZUV User s Manual Section 3 Setting the System Environment MEMO...
Page 123: ...5 15 ZUV User s Manual Section 5 APPENDIX Section 5 INDEX MEMO...
Page 125: ......