3-4
Sect
ion 3
SETUP
ZUV
User’s Manual
Section 3
Setting the Irradiation Conditions
Setting the Irradiation Conditions
Simultaneous adhesion is available for multiple locations under differing conditions by
setting the irradiation conditions.
Two ways of irradiation are provided: constant irradiation, which irradiates at constant
power for a certain time, and pattern irradiation, which irradiates by gradating the power
with a pattern setting of power and time.
Be sure to set the channel, for which irradiation is not performed, to [OFF] in the LOCK mode by
selecting -[CH SET] and then selecting each of the channels from [1CH to 4CH].
Continuous irradiation of
UV light for a certain time
at constant irradiation
power
Pattern irradiation (linear)
Irradiation of UV light by
gradating irradiation power
Irradiation at certain
intervals
Irradiation of UV light by
converting irradiation power
to analog values
Irradiation power
(%)
Irradiation time (s)
(max. 16)
Irradiation power
(%)
Irradiation time (s)
STEP1
STEP2
STEP3
STEP16
(max. 16 steps)
Irradiation power
(%)
Irradiation time (s)
(max. 16 steps)
STEP1
STEP2
STEP3
STEP4 STEP5
Irradiation power
(%)
Irradiation time (s)
Pattern irradiation (steps)
Pattern irradiation (steps)
Constant irradiation
Summary of Contents for ZUV Series
Page 1: ...Smart Curing System User s Manual Cat No Z281 E1 02 ZUV Series Mega Power Type...
Page 18: ...16 ZUV User s manual CONTENTS Introduction CONTENTS MEMO...
Page 44: ...2 18 Section 2 ZUV BASIC OPERATION ZUV User s Manual Section 2 Operating Modes MEMO...
Page 68: ...3 24 Section 3 SETUP ZUV User s Manual Section 3 Setting the System Environment MEMO...
Page 123: ...5 15 ZUV User s Manual Section 5 APPENDIX Section 5 INDEX MEMO...
Page 125: ......