4-6
Section 4
CONNECTING TO EXTERNAL DEVICES
ZUV
User’s Manual
Section 4
Connection by an I/O Terminal Block
Timing Charts
The following shows the timing charts when communication is performed with external
devices.
■
Ready output/display
Ready output turns ON when the controller is ready for irradiation.
• The response time is within 200 ms of the change in state of the ready output signal.
• The ready output of all channels turns ON after irradiation of all channels on the
irradiation target (other than OFF) ends.
• The ready output signal is always OFF for channels whose irradiation setting is OFF.
• The response time is within 200 ms of the change in state of the ready output signal.
• The ready output of the target channel turns ON after the irradiation of the target
channel ends.
• The ready output signal is always OFF for channels whose irradiation setting is OFF.
CH1 irradiation
CH1 READY
CH2 irradiation
CH2 READY
200 ms
<Batch Control>
CH1 irradiation
CH1 READY
CH2 irradiation
CH2 READY
200 ms
200 ms
<Individual Control>
Summary of Contents for ZUV Series
Page 1: ...Smart Curing System User s Manual Cat No Z281 E1 02 ZUV Series Mega Power Type...
Page 18: ...16 ZUV User s manual CONTENTS Introduction CONTENTS MEMO...
Page 44: ...2 18 Section 2 ZUV BASIC OPERATION ZUV User s Manual Section 2 Operating Modes MEMO...
Page 68: ...3 24 Section 3 SETUP ZUV User s Manual Section 3 Setting the System Environment MEMO...
Page 123: ...5 15 ZUV User s Manual Section 5 APPENDIX Section 5 INDEX MEMO...
Page 125: ......