4-8
Section 4
CONNECTING TO EXTERNAL DEVICES
ZUV
User’s Manual
Section 4
Connection by an I/O Terminal Block
■
Trigger signal input priority conditions
Select which of preset time or interrupt input signal to give priority to for trigger signal
input.
<When priority is set to time>
<When priority is set to interrupt input signal>
Setting trigger signal input priority conditions p.3-21
TRG1 ON
CH1 irradiation
CH1 READY
40 ms/120 ms
40 ms/120 ms
40 ms/120 ms
Set irradiation end time
TRG1 ON
CH1 irradiation
CH1 READY
40 ms/120 ms
40 ms/120 ms
40 ms/120 ms
Set irradiation end time