Installation and Connections/Wiring
RS-485 Port
The method for connection to the RS-485 port of another Amplifier Unit when multiple CIDRW Heads
are used is explained here.
The maximum total length of RS-485 cable is 50 m.
• Connector
Prepare a V640-A90 (can be purchased as an accessory) as the connector for the RS-485 port on the
Amplifier Unit.
Refer to page 39.
The pin arrangement is shown below.
To the RS-485 port
Amplifier Unit
To the RS-232C port
CIDRW Controller
Connector
Name
Function
-
Connect to the minus line of another Amplifier Unit.
+
Connect to the plus line of another Amplifier Unit.