![background image](http://html1.mh-extra.com/html/omron/v640-hs61/v640-hs61_user-manual_741375073.webp)
71
CIDRW System
User’s Manual
SECTION 3
Communica
tions
Te
s
t
SECTION 3
Preparing for Communications
Communications Test between ID Tags and CIDRW System
Send a command from the host device and check that normal communications with the ID Tag is pos-
sible.
When SECS Is Used
• Read ID
The host device sends a
Read ID Request
message to the CIDRW Controller for Head 1. The CIDRW
Head 1 reads the ID, and the CIDRW Controller returns the ID to the host device.
• Read Data
The host device sends a
Read Data Request
message to the CIDRW Controller for Head 1, DataSeg
S01 and Datalength 8. The CIDRW Head 1 reads the data, and the CIDRW Controller returns the data
to the host device.
CIDRW Controller
Host
S18, F9 Read ID Request
Target ID="00"
S18, F10 Read ID Data
MID="XYZ00001"
CIDRW Controller
Host
S18, F5 Read Request
Target ID="01"
Dataseg="S01"
Datalength="8"
S18,F6 Read Data
Data="yyyyyyyy"