49
CIDRW System
User’s Manual
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
SECTION 2
Installation and Connections/Wiring
Multi-connection Port
The method for connecting to an Amplifier Unit is explained here.
• Connector
Pin No.
Name
Function
5
-
No wiring is required. (Short with terminal 2 within the circuit)
4
+
No wiring is required. (Short with terminal 1 within the circuit)
3
GR
Ground to 100
Ω
or less.
2
-
Connect to the minus line of the Amplifier Unit.
1
+
Connect to the plus line of the Amplifier Unit.
Link Unit
Amplifier Unit
To the RS-485 port
To multi-connection port