![background image](http://html1.mh-extra.com/html/omron/v640-hs61/v640-hs61_user-manual_741375096.webp)
94
SECTION 4
When SECS Is
N
ot U
sed
CIDRW System
User’s Manual
SECTION 4
Reading from/Writing to ID Tags
TEST
Performs a communications test on communications between the host device and Amplifier Unit.
When an Amplifier Unit receives a test command, it sends the response code and command test data
to the host device as the response.
* Number of data n < 136 (2-character units)
The response code (when normal: 00) and the received test data are returned.
Example: Testing by sending the data 12345678 to node No.1
SOH
Node No.
Command code
Test data
FCS
CR
Data 1
•••
Data n
01h
1
0
0Dh
Parameter Description
Parameter
Description
Test data
The data to be sent in the test is specified with a hexadecimal value. (270 characters max.)
However, note that odd numbers of characters cannot be used.
SOH
Node No.
Response
code
Test data
FCS
CR
Data 1
•••
Data n
01h
0
0
0Dh
SOH
Node No.
Command code
Test data
FCS
CR
Data 1
Data 2
Data 3
Data 4
01h
0
1
1
0
1
2
3
4
5
6
7
8
0
8
0Dh
SOH
Node No.
Response
code
Test data
FCS
CR
Data 1
Data 2
Data 3
Data 4
01h
0
1
0
0
1
2
3
4
5
6
7
8
0
9
0Dh
Command
Response
Command
Response
Summary of Contents for V640-HS61
Page 14: ...12 INTRODUCTION Reading this Manual CIDRW System User s Manual INTRODUCTION MEMO...
Page 120: ...118 SECTION 5 When SECS Is Not Used CIDRW System User s Manual SECTION 5 Troubleshooting MEMO...
Page 171: ...CIDRW System User s Manual SECTION 6 Protective Construction SECTION 6 Appendix 169 MEMO...
Page 173: ......