User’s Manual
SECTION 5
Troubleshooting
When SECS Is Used
Errors are indicated by the contents of the CIDRW Controller response messages, and by the indicators.
List of Error Messages
When responses are made to messages sent by the CIDRW Controller, errors are expressed by the
contents of error messages and the nature of the SSACK response.
Controller Indicators
If an error or alarm has occurred at the CIDRW Controller, the indicators on the front of the Controller
light.
S
F
Direction
SECS
II
names
1
0
S,H
←
E
Abort Transaction
9
0
S,H
→
E
Abort Transaction
9
1
S,H
←
E
Unrecognized Device ID
9
3
S,H
←
E
Unrecognized Stream Type
9
5
S,H
←
E
Unrecognized Function Type
9
7
S,H
←
E
Illegal Data
9
9
S,H
←
E
Transaction Timer Timeout
9
11
S,H
←
E
Data Too Long
18
0
S,H
←
E
Abort Transaction
Name
Function
OPERATING (green)
Lit when the operation status (status model) of the CIDRW system is operating.
ALARMS (green)
Lit when the status in AlarmStatus of the CIDRW system is Alarm (1).
BUSY (green)
Lit when the status in OperationalStatus of the CIDRW system is BUSY.
ERROR (red)
When a processing error is detected (when SSACK is other than NO), this indicator is lit for 50 ms.