47
CIDRW System
User’s Manual
SE
CTION 2
Con
n
ec
tions
a
nd Wiring
SECTION 2
Installation and Connections/Wiring
• Wiring for Connection to a CIDRW Controller
The cable length should be no greater than 15 m.
Pin No.
Signal name
Symbol
Signal direction
Remarks
1
—
NC
—
Not connected
2
Receive data
RD
Input
3
Send data
SD
Output
4
—
NC
—
Not connected
5
Signal ground
SG
—
6
—
NC
—
Not connected
7
Request send
RS
Output
Always ON during normal operation
8
Send enabled
CS
Input
9
—
NC
—
Not connected
Recommended model
Manufacturer
Model
Cable
Hitachi Cable
CO-MA-VV-SB 5PX28AWG
Connector
Socket
OMRON
XM2D-0901
Hood
XM2S-0913
Link Unit
V700-L11
D-SUB, 9-pin, female
Socket type #4-40
Name
Pin No.
NC
1
RD
2
SD
3
NC
4
SG
5
NC
6
RS
7
CS
8
NC
9
CIDRW Controller
V700-L22
D-SUB, 9-pin, female
Socket type #4-40
Pin No.
Name
1
NC
2
RD
3
SD
4
NC
5
SG
6
NC
7
RS
8
CS
9
NC
Ground shielded wires at the CIDRW Controller side.