61
V500-R2 series
User’s Manual
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
Section 4
Setting Method
Hatching parts are the changed point from the factory default setting.
Collective setting
Menu sheet
Command
Setting for connecting link unit (V700-L12)
_EDA_
[EDA
Item
Setting content
Types of code, which is possible to
read
EAN/UPC, CODE39, Codabar (NW-7), Industrial2of5(STF), ITF
Number of reading digits
No designated number of digits
Detail
condition
CODE39 detail setting Invalid C/Dof CODE39
Transfer C/D of CODE39
Transfer ST/SP of CODE39
Codabar (NW-7) detail
setting
Invalid C/D of Codabar (NW-7)
Transfer C/D of Codabar (NW-7)
Transfer ST/SP of Codabar (NW-7) (abcd/abcd)
ITF/
Industrial2of5(STF)
detail setting
Invalid C/D of ITF/Industrial2of5(STF)
Transfer C/D of ITF/Industrial2of5(STF)
Reading
condition
Reading system
Trigger reading
Reading operation
Single reading
Reading valid time
T 2 sec.
Number of reading
coincidence
Twice (Verification: once)
Communication
condition
Communication speed 9600 bps
Data length
8-bit
Parity
Even number
Stop bit length
1-bit
Header
None
Footer
CR
Transfer number of
digits
Not transferred
RS/CS control
None
CS waiting time
Infinity
Communication
protocol
No protocol system
Process when reading
is NG
Transfer ? (CR), > (CR)
LED illumination
LED illumination time after decoding is 200 ms.
Buzzer sound
Buzzer sound duration after decoding is 200 ms.
Buzzer sound volume
Max.
Buzzer frequency
3 kHz, 2 kHz
External trigger signal
Negative logic (L active)
READ OK/NG signal output
Output
READ OK/NG signal output system
Trigger synchronous system, positive logic (H active)