113
V500-R2 series
User’s Manual
Sec
tion
5
How to Use Command
L
in
k
Un
it
V7
00-
L1
2
Section 5
Example of System Configuration
Cables
Recommended parts
Wiring method
1.
Attach crimping terminals on a cable where coating is peeled.
2.
Insert each wire to each connector hole with attention to
the direction of the connector.
3.
Tighten the screws for fixing the connector cable.
Appropriate tightening torque is approx. 0.3 N.m.
Recommended driver
4.
Connect the connector to the link unit.
Fit the direction of the connector on the link unit side
and the cable, insert firmly to the end and tighten the
fixing screws.
Model
Manufacturer
Cable
RS-485 signal line
MVVS 2CX0.5SQ
Tachii Electric Wire Co., Ltd.
Frame ground wire
(Cables of AWG22 to 20)
Crimping
terminal
When connecting one
wire to one terminal
AI0.5-8WH
PHOENIX CONTACT
When connecting two
wires to one terminal
AI-TWIN2 x 0.5-8WH
Tools for crimping terminal
CRIMPFOX UD6
When connecting with RS-485 interface of the upper equipment
The upper equipment should be in data reception condition
within 15 ms after data transmission. This control should be
performed for normal operation.
Manufacturer
Model
OMRON Corporation
XW4Z-00C
Uncoupling the connector
Loosen two fixing screws completely and pull
off the connector straight back holding the
protrusion. When it is not pulled off easily,
hold the link unit body and pull it again.
Compact slotted screwdriver,
its tip is constant in thickness
0.6 mm
3.5 mm
Front side
Side face
Fixing screw
Summary of Contents for V500-R2 Series
Page 1: ...Z334 E1 01A Cat No Fixed Laser Type Barcode Reader User s Manual V500 R2 Series...
Page 18: ...16 V500 R2 series User s Manual Introduction Contents Introduction MEMO...
Page 36: ...34 Section 2 Installation V500 R2 series User s Manual Section 2 Wiring and Installation MEMO...
Page 143: ......