Section 4
Setting Method
Setting for the number of reading digits
When the number of reading digits is fixed, all codes having other lengths than that
specified can be rejected. Up to two reading digits can be set.
This setting is effective for codes such as Interleaved 2 of 5 for which security against
partial reading is insufficient.
While the number of reading digits to be fixed can be set by reading the code, the
number of reading digits cannot be set with a command since a code of the necessary
length must be read.
E.g.: The following describes the steps for fixing the number of reading digits.
Error message - Decoding failure
_TI_
TI
Not transmit an error message (Factory default setting)
_TG_
TG
• To read codes of a known length, it is recommended that the number of digits be fixed.
• While the number of reading digits to be fixed can be set by reading the code, it is not affected by a
detail setting (p.64) for reading codes, including “Transfer ST/SP”, “Not transfer ST/SP”, “Transfer C/
D” and “Not transfer C/D”.
• Fixing the number of reading digits does not affect WPC (JAN/EAN/UPC) or other fixed-length codes.
Menu sheet
Command
Fixed number of digits OFF for all codes (Factory default setting)
_H0_
H0
Fixed number of digits ON for all codes
_H1_
None
Menu sheet
Command
Setting start (ZZ)
Fixed number of digits ON (H1)
Read the first code of the necessary length
Read the second code of the necessary length
Setting end (ZZ)