58
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
V500-R2 series
User’s Manual
Section 4
Setting Method
Return to the factory default setting
Factory default setting
Menu sheet
Command
Return to the factory default setting
_U2_
U2
Item
Setting content
Readable code types
JAN/UPC (A and E)/EAN(13 and 8), CODE39, Codabar(NW-7),
Industrial2of5, ITF, CODE128, CODE93, and GS1 DataBar (RSS)
(composite is excluded)
Detail
conditions
UPC/EAN detail
settings
UPC-A: Transfer C/D without an 0 in the beginning
UPC-E: Transfer C/D without an 0 in the beginning
EAN-13: Transfer C/D
EAN-8: Transfer C/D
CODE39 detail
settings
Not calculate C/D
Transfer C/D
Not transfer ST/SP
Codabar (NW-7) detail
settings
Not calculate C/D
Transfer C/D
Not transfer ST/SP
Data character of at least 5 digits
Industrial2of5(STF)
detail settings
Not calculate C/D
Transfer C/D
GS1-Databar(RSS)
detail settings
Transfer C/D
GS1-128(EAN128)
detail settings
Disable FNC1 to GS conversion
Reading
conditions
Reading method
(normal reading /
trigger reading)
Trigger reading
Number of reading
verification times
Once
Reading operation
Single reading
Failed reading
Transmit nothing
Number of reading
digits
Not specified
Reading valid time
2 seconds
Plural reading reset
time
6 frames
LED
READ OK LED illumination time: 200 ms
Buzzer
Enable the buzzer
Single-tone buzzer
Buzzer sound duration: 50 ms
Buzzer sound volume: Max
Summary of Contents for V500-R2 Series
Page 1: ...Z334 E1 01A Cat No Fixed Laser Type Barcode Reader User s Manual V500 R2 Series...
Page 18: ...16 V500 R2 series User s Manual Introduction Contents Introduction MEMO...
Page 36: ...34 Section 2 Installation V500 R2 series User s Manual Section 2 Wiring and Installation MEMO...
Page 143: ......