![background image](http://html1.mh-extra.com/html/omron/v500-r2-series/v500-r2-series_user-manual_741439071.webp)
69
V500-R2 series
User’s Manual
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
Section 4
Setting Method
Setting for the number of times of reading
coincidence
When reading result coincides the number of times you have set, the reading result is
output to the RS-232C interface.
The verification system is AND verification (Continuous coincidence system). (This
cannot be changed.)
Menu sheet
Command
Reading once and verification zero times
_X0_
X0
Reading twice and verification once (Factory default setting)
_X1_
X1
Reading three times and verification twice
_X2_
X2
Reading four times and verification three times
_X3_
X3
Reading five times and verification four times
_BS_
BS
Reading six times and verification five times
_BT_
BT