Section 3
Function Explanation
Test Reading Function
You can check how stably the subject bar code can be read.
Read a bar code at resting state for one sec. and calculate the reading rate.
To enter reading measurement mode using a command
1.
Install the bar code at a reading position.
2.
Enter command ".V".
Mode enters to reading rate measurement mode.
Reading rate of every one sec. is measured.
3.
To finish the reading rate measurement mode, enter command ".W" or re-start the bar
code reader.
Return to the normal measurement mode.
Output format
Reading rate of every one sec. is output to the upper equipment, while in reading rate
measurement mode.
Data, which detected most during measurement mode, is “correct reading data”.
Communication data format
Do not execute write command "Z2" to nonvolatile memory.
A sample setting condition is overwritten and stored, which erases the already set reading condition.
Number of decoded time in one sec.
Of those, correct reading data (*) detected rate = Reading rate
Correct reading data (*)
ESC [ 3 A CR 500d SPACE Ok: 93.5% CR
ABCDE
CR