25
V500-R2 series
User’s Manual
Sect
ion
1
Ra
ti
ng
/Pe
rfo
rma
nc
e
Section 1
Product Overview
Reading angle performance
Pitch angle
In the following conditions, readable up to
α
= 30° on either side.
• Bar code:
Resolution = 0.25 mm, CODE39 (9 digits), PCS = 0.9
• Reading distance:
110 mm from the case end
• Installation condition: Skew angle
β
= 15°, tilt angle
γ
= 0°, curvature R =
∞
Skew angle
In the following conditions, readable up to
β
= ± 60°. However, range from
β
= -8° to +10° is
an area difficult to read due to regular reflection.
• Bar code:
Resolution = 0.25 mm, CODE39 (9 digits), PCS = 0.9
• Reading distance:
110 mm from the case end
• Installation condition: Pitch angle
α
= 0°, tilt angle
γ
= 0°, curvature R =
∞
−
α
+
α
−
β
+
β