Références des produits
Versions monobloc
GAT -R41-E-U04-xx/2 (ETSI) Modèle TTL (Clock&Data / Wiegand)
GAT -R42-E-U04-xx/2 (ETSI) Modèle RS232
GAT -R43-E-U04-xx/2 (ETSI) Modèle RS485
GAT -R51-E-U04-xx/2 (FCC) Modèle TTL (Clock&Data / Wiegand)
GAT -R52-E-U04-xx/2 (FCC) Modèle RS232
GAT -R53-E-U04-xx/2 (FCC)
Modèle RS485
Versions portique
GAT -R41-F-U04-xx/2 (ETSI)
Modèle TTL (Clock&Data / Wiegand)
GAT -R42-F-U04-xx/2 (ETSI) Modèle RS232
GAT -R43-F-U04-xx/2 (ETSI)
Modèle RS485
GAT -R51-F-U04-xx/2 (FCC) Modèle TTL (Clock&Data / Wiegand)
GAT -R52-F-U04-xx/2 (FCC) Modèle RS232
GAT -R53-F-U04-xx/2 (FCC)
Modèle RS485
Caractéristiques
Alimentation :
+9 Vdc à +36 Vdc
(+12 Vdc Typique)
Consommation :
2.5 A sous +12 Vdc
Communication:
RS485 (L+ & L-)
RS232 (TD & RD)
TTL (Wiegand / Clock & Data)
Raccordement :
Bornier à vis 2 points & Bornier à vis 8 points
Pas de 5,08 mm
Température de fonctionnement :
-20 °C / +55°C
-4,00 °F / +131,00°F
Indice de protection :
IP66 / Ik07
Puce lue :
EPC1 Gen2 (ISO 18000-6C) 96 bits max.
Relais:
1 A max sous 30 Vdc.
Type de câble préconisé
Utiliser du câble multiconducteur blindé par tresse, reliée à la masse du concentrateur.
Déport max RS485 :
1000 m. à 9600 bauds (
SYT2 6/10 ° conseillé
)
Déport max RS232 :
15 m.
(
SYT2 6/10 ° conseillé
)
Wiegand / Clock & Data:
Communication
Pour plus d’informations concernant le dialogue avec le lecteur, veuillez consulter la
spécification du protocole.
Vue générale
Les différents composants et les connexions du lecteur sont ci-dessous.
Pour plus d’informations, se reporter au chapitre
Détails
.
Products references
One antenna variants
GAT -R41-E-U04-xx/2 (ETSI)
TTL Model (Clock&Data / Wiegand)
GAT -R42-E-U04-xx/2 (ETSI)
RS232 Model
GAT -R43-E-U04-xx/2 (ETSI)
RS485 Model
GAT -R51-E-U04-xx/2 (FCC)
TTL Model (Clock&Data / Wiegand)
GAT -R52-E-U04-xx/2 (FCC)
RS232 Model
GAT -R53-E-U04-xx/2 (FCC)
RS485 Model
Gate variants
GAT -R41-F-U04-xx/2 (ETSI)
TTL Model (Clock&Data / Wiegand)
GAT -R42-F-U04-xx/2 (ETSI)
RS232 Model
GAT -R43-F-U04-xx/2 (ETSI)
RS485 Model
GAT -R51-F-U04-xx/2 (FCC)
TTL Model (Clock&Data / Wiegand)
GAT -R52-F-U04-xx/2 (FCC)
RS232 Model
GAT -R53-F-U04-xx/2 (FCC)
RS485 Model
Characteristics
Power supply:
+9 Vdc up to +36 Vdc
(+12 Vdc Typical)
Consumption:
2.5 A Under +12 Vdc
Communication:
RS485 (L+ & L-)
RS232 (TD & RD)
TTL (Wiegand / Clock & Data)
Pin out:
Connector 2 points & Connector 8 points
Thread 5.08 mm / 0.2000 in
Temperature:
-20 °C / +55°C
-4.00 °F / +131.00°F
Protection:
IP66 / Ik07
Chip:
EPC1 Gen2 (ISO 18000-6C) 96 bits max.
Relay:
1 A max under 30 Vdc.
Recommended cables
Use a multi-conductor cable, pair shielded.
Max length RS485:
1000 m / 3 280.84 ft at 9600 bps (
SYT2 AWG24 Recommended
)
Max length RS232:
15 m / 49.21 ft.
(
SYT2 AWG24 recommended
)
Wiegand / Clock & Data:
Communication
More details about reader
’s communication are available in the protocol specification
Overview
The different components and the connexions are represented below.
For more details, please refer to the
Details
chapter.
0
Alimentation
1
GND
2
GND
3
GND
4
IN1
5
L+/TD/Data/D0 Voie 1
6
L-/RD/Clock/D1 Voie 1
7
NC
8
NC
9
NC
10
NC
11
NC
12
NC
13
NC
14
NC
15
NC
16
NC
17
NC
18
NC
19
NC
20
NC
21
NC
22
NC
23
NC
24
NC
25
NC
26
NC
27
NC
28
NC
29
NC
30
NC
31
NC
32
NC
33
NC
A
Vis de fixation TORX M3x12
B
Coupleur UHF
C
Carte alimentation
D
Carte Interface
E
Antenne
F
LED de visualisation
G
Information visuelle communication Coupleur UHF
H
Information visuelle communication Host
I
Buzzer
J
Bornier de connexion
K
Presse-étoupes
L
Résistance de fin de lignes
M
Switch SW1
N
Commutateur de filtrage
O
Voie IN 1-4
P
Relais 1-4
A
Screws TORX M3x12
B
UHF Coupler
C
Power supply board
D
Interface board
E
Antenna
F
Led of visualization
G
Indication for communication with the UHF coupler
H
Indication for communication with the Host
I
Buzzer
J
Connector
K
Stuffing box
L
End of line resistor
M
Switch SW1
N
Filtering Switch
O
Lane IN 1-4
P
Relay 1-4
1 paire 6/10° - 30 m max
1 paire 9/10° - 50 m max
2 paires 6/10° - 60 m max
2 paires 9/10° - 100 m max
3 paires 6/10° - 100 m max
1 pair AWG24 - 98,43 ft / 30 m max
1 pair AWG35 - 164,04 ft / 50 m max
2 pairs AWG24 - 196,85 ft / 60 m max
2 pairs AWG35 - 328,08 ft / 100 m max
3 pairs AWG24 -328,08 ft / 100 m max
0
Power Supply
1
GND
2
GND
3
GND
4
IN1
5
L+/TD/Data/D0 Voie 1
6
L-/RD/Clock/D1 Voie 1
7
NC
8
NC
9
NC
10
NC
11
NC
12
NC
13
NC
14
NC
15
NC
16
NC
17
NC
18
NC
19
NC
20
NC
21
NC
22
NC
23
NC
24
NC
25
NC
26
NC
27
NC
28
NC
29
NC
30
NC
31
NC
32
NC
33
NC