Appendices
A - 30
NX-series IO-Link Master Unit User’s Manual (W567)
*2. When an IO-Link device is connected, the vendor name and product name are written. Even if the IO-Link device is dis-
connected, its vendor name and product name are retained. This enables you to check the vendor name and product
name of the connected IO-Link device before replacement if you replace an IO-Link device.
*3. When an IO-Link device is connected, the vendor name and product name are written. The vendor name and product
name of a currently connected IO-Link device can be checked. When the IO-Link device is disconnected, 64 zeros (0)
are stored. With the ASCII code, for example, this will be 64 NUL.
Index
(hex)
Subindex
(hex)
Object name
Default
value
Data range
Unit
Data
type
Access
I/O allo-
cation
Data
attribute
5014
---
Port1 Message for IO-Link
device
*1
---
---
---
---
---
00
Number of Entries
11 hex
11 hex
---
USINT
RO
Not pos-
sible
---
01
Control
00 hex
00 to 03 hex
*2
---
USINT
RW
Not pos-
sible
N
02
Status
00 hex
00 to 05 hex
*3
---
USINT
RO
Not pos-
sible
---
03
Index
*4
0000
hex
0000 to FFFF hex
---
UINT
RW
Not pos-
sible
N
04
SubIndex
*5
00 hex
00 to FF hex
---
USINT
RW
Not pos-
sible
N
05
Length
*6
00 hex
00 to FF hex
---
USINT
RW
Not pos-
sible
N
06
Data
*7
*8
*9
---
ARRAY
[0..231]
OF
BYTE
RW
Not pos-
sible
N
07
Error Code
*10
0000
hex
0000 to FFFF hex
---
UINT
RO
Not pos-
sible
---
10
Timeout
*11
0000
hex
0000 to FFFF hex
ms
UINT
RW
Not pos-
sible
N
11
Sequence No
*12
00 hex
00 to FF hex
---
USINT
RW
Not pos-
sible
N
5015
---
Port2 Message for IO-Link
device
*1
---
---
---
---
---
00
Number of Entries
11 hex
11 hex
---
USINT
RO
Not pos-
sible
---
01
Control
00 hex
00 to 03 hex
*2
---
USINT
RW
Not pos-
sible
N
02
Status
00 hex
00 to 05 hex
*3
---
USINT
RO
Not pos-
sible
---
03
Index
*4
0000
hex
0000 to FFFF hex
---
UINT
RW
Not pos-
sible
N
04
SubIndex
*5
00 hex
00 to FF hex
---
USINT
RW
Not pos-
sible
N
05
Length
*6
00 hex
00 to FF hex
---
USINT
RW
Not pos-
sible
N
06
Data
*7
*8
*9
---
ARRAY
[0..231]
OF
BYTE
RW
Not pos-
sible
N
07
Error Code
*10
0000
hex
0000 to FFFF hex
---
UINT
RO
Not pos-
sible
---
10
Timeout
*11
0000
hex
0000 to FFFF hex
ms
UINT
RW
Not pos-
sible
N
11
Sequence No
*12
00 hex
00 to FF hex
---
USINT
RW
Not pos-
sible
N
Summary of Contents for NX-ILM400
Page 12: ...Manual Structure 10 NX series IO Link Master Unit User s Manual W567...
Page 36: ...Revision History 34 NX series IO Link Master Unit User s Manual W567...
Page 38: ...Sections in this Manual 36 NX series IO Link Master Unit User s Manual W567...
Page 52: ...2 Specifications 2 4 NX series IO Link Master Unit User s Manual W567...
Page 58: ...3 Part Names and Functions 3 6 NX series IO Link Master Unit User s Manual W567...
Page 120: ...7 Troubleshooting 7 8 NX series IO Link Master Unit User s Manual W567...
Page 126: ...8 Inspection and Maintenance 8 6 NX series IO Link Master Unit User s Manual W567...
Page 170: ...Appendices A 44 NX series IO Link Master Unit User s Manual W567...
Page 171: ...I 1 I NX series IO Link Master Unit User s Manual W567 Index...
Page 174: ...I 4 NX series IO Link Master Unit User s Manual W567 Index...
Page 175: ......