![background image](http://html1.mh-extra.com/html/omron/k3hb/k3hb_technical-communications-users-manual_743344050.webp)
2-5
List of Settings
Section 2
Lis
t of
Se
tting
s
Note
The values beginning with H’ in the
Monitor/Setting range
column are used when setting or monitoring
data via communications.
C4
0005
Scaling
input value
A2
inp
.
a2
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
X (VD):
199
.
99
X (AD):
199
.
99
X (VA):
400
.
00
X (AA):
10
.
000
V:
199
.
99
S:
20
.
000
Accord-
ing to the
input type
Accord-
ing to
the
input
type
x
0006
Scaling dis-
play value
A2
dsp
.
a2
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
X (VD):
19999
X (AD):
19999
X (VA):
4000
X (AA):
10000
V:
19999
S:
20000
---
---
x
0007
Input type B
in-tb
H’00000000: 0 to 20 mA(0),
H’00000001: 4 to 20 mA(1),
H’00000002: 0 to 5 V(2), H’00000003:
1 to 5 V(3), H’00000004:
±
5 V(4),
H’00000005:
±
10(5)
0-20
,
4-20
,
0-5
,
1-5
,
5
,
10
4-20
---
---
x
x
x
0008
Scaling
input value
B1
inp.b1
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
20
.
000
Accord-
ing to the
input type
Accord-
ing to
the
input
type
x
x
x
0009
Scaling dis-
play value
B1
dsp.b1
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
4000
---
---
x
x
x
000A
Scaling
input value
B2
inp.b2
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
20
.
000
Accord-
ing to the
input type
Accord-
ing to
the
input
type
x
x
x
000B
Scaling dis-
play value
B2
dsp.b2
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
20000
---
---
x
x
x
000C
Constant K
k
H’FFFFB1E1 to H’0001869F (
−
19,999
to 99,999)
:9999
to
99999
0
---
---
x
x
x
000D
Decimal
point posi-
tion
dp
H’00000000 to
H’00000004: 0 to 4
,,,,,
,
,,,,.,
,
,,,.,,
,
,,.,,,
,
,.,,,,
X (VD):
,,,.,,
X (AD):
,,,.,,
X (VA):
,,,,.,
X (AA):
,,.,,,
V:
,,,.,
S:
,,.,,,
---
---
x
000F
Tempera-
ture units
d-u
H’00000000
°
C(0),
H’00000001: F(1)
c
,
f
c
---
---
x
x
x
000E
Compara-
tive output
pattern
out-p
H’00000000: standard output(0),
H’00000001: zone output(1),
H’00000002: zone output(2)
nomal
,
zone
,
level
nomal
---
---
Variable
type
Address
Parameter
name
Char-
acter
Monitor/Setting range
Character
Default
setting
Decimal
point
Unit
Model
X
V
S
H
Summary of Contents for K3HB
Page 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Page 3: ...iv...
Page 15: ...xvi...
Page 19: ...xx...
Page 21: ...Part 1 CompoWay F...
Page 69: ...Part 2 DeviceNet...
Page 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Page 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Page 127: ...Part 3 BCD Output...
Page 147: ......