1-19
Commands and Responses (CompoWay/F Communications)
Section 1-9
Co
m
p
o
W
a
y
/F
Co
m
m
u
n
ica
tio
n
s
Response
Response codes: The above indicates a normal end. For the response codes,
see
1-7 Operation Commands (CompoWay/F Communications)
1-9-13 Zero Execute/Cancel
Command
This command is used to execute/cancel the forced zero and tare zero func-
tions. The results of the command will depend on the status of the tare zero
setting, as shown below.
This command can be used only in setting area 0. An operation error will
occur in the following situations.
• When there is no-measurement status, there is an input error, or a mea-
surement is outside the display range (but zero cancel is possible.)
• When a RESET or HOLD input is ON
• When the command is used in setting area 1
Response
Response codes: The above indicates a normal end. For the response codes,
see
1-7 Operation Commands (CompoWay/F Communications)
1-9-14 Software Reset
Command
A software reset causes the same operation as turning the power off and on.
This command can be used in both setting area 0 and setting area 1.
To use this command, “Write via communications” must be enabled using the
“Write via communications” operation command.
Response
(No response)
A response is not returned to this operation command.
"30"
"05"
"0000"
Response code
SRC
MRC
Related information
Description
“00”
Zero cancel
“01”
Zero execute
Tare
zero
Commands executed in order left to right.
Zero execute
Zero execute
Zero cancel
Zero cancel
OFF
Forced zero ON
Forced zero ON
Forced zero OFF Forced zero OFF
ON
Forced zero ON
Tare zero ON
Tare zero OFF
Forced zero OFF
"30"
"05"
SRC
"03"
Command
code
Related
information
MRC
"30"
"05"
"0000"
Response code
SRC
MRC
"30"
"05"
SRC
"06"
"00"
Command
code
Related
information
MRC
Summary of Contents for K3HB
Page 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Page 3: ...iv...
Page 15: ...xvi...
Page 19: ...xx...
Page 21: ...Part 1 CompoWay F...
Page 69: ...Part 2 DeviceNet...
Page 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Page 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Page 127: ...Part 3 BCD Output...
Page 147: ......