![background image](http://html1.mh-extra.com/html/omron/k3hb/k3hb_technical-communications-users-manual_743344041.webp)
1-20
Commands and Responses (CompoWay/F Communications)
Section 1-9
Co
m
p
o
W
a
y
/F
C
o
m
m
u
n
icat
io
ns
1-9-15 Move to Setting Area 1
Command
Use this command to move to setting area 1.
The command is used in setting area 0. Nothing happens if the command is
used in setting area 1.
If the command is used when “Initial setting protect” is set to 2 (Disable move
to input initial setting level), an operation error will result.
To use this command, “Write via communications” must be enabled using the
“Write via communications” operation command.
Response
Response codes: The above indicates a normal end. For the response codes,
see
1-7 Operation Commands (CompoWay/F Communications)
1-9-16 Move to Protect Level
Command
Use this command to move to protect level.
This command is used in setting area 0. If used in setting area 1, an operation
error will result.
To use this command, “Write via communications” must be enabled using the
“Write via communications” operation command.
Response
Response codes: The above indicates a normal end. For the response codes,
see
1-7 Operation Commands (CompoWay/F Communications)
1-9-17 Initialize Settings
Command
This returns all settings to the initial settings.
This command is used in setting area 1. If used in setting area 0, an operation
error will result.
To use this command, “Write via communications” must be enabled using the
“Write via communications” operation command.
"30"
"05"
SRC
"07"
"00"
Command
code
Related
information
MRC
"30"
"05"
"0000"
Response code
SRC
MRC
"30"
"05"
SRC
"08"
"00"
Command
code
Related
information
MRC
"30"
"05"
"0000"
Response code
SRC
MRC
"30"
"05"
SRC
"0B"
"00"
Command
code
Related
information
MRC
Summary of Contents for K3HB
Page 2: ...K3HB Digital Indicators Communications User s Manual Revised March 2005...
Page 3: ...iv...
Page 15: ...xvi...
Page 19: ...xx...
Page 21: ...Part 1 CompoWay F...
Page 69: ...Part 2 DeviceNet...
Page 95: ...6 10 Ladder Programming Examples Section 4 3 Remote I O Com munications...
Page 111: ...8 8 Message Communications Performance Section 6 2 Communications Performance...
Page 127: ...Part 3 BCD Output...
Page 147: ......