Explicit Message Communications
Section 2-6
List of Operation
Commands
The following table lists the explicit messages operation commands.
1.
The unit number specified by the Instance ID must be set to between 0001
Hex and 0010 Hex.
2.
An error will occur if the unit number of an E39-TM1 Terminal Block Unit is
specified.
Explicit
message
Function
Command
Service
code
Instance
ID
Operation
command
data
Adjust Maxi-
mum Sensitivity
Specifies the unit number as the
instance ID, and sets the maxi-
mum sensitivity when the com-
mand is sent.
16
Unit
number
30
Teach One
Point
Specifies the unit number as the
instance ID, and teaches one
point when the command is sent.
16
Unit
number
31
Teach First
Point
Specifies the unit number as the
instance ID, and teaches the first
point of two-point teaching when
the command is sent.
16
Unit
number
32
Teach Second
Point
Specifies the unit number as the
instance ID, and teaches the sec-
ond point of two-point teaching
when the command is sent.
16
Unit
number
33
Teach First
Position
Specifies the unit number as the
instance ID, and teaches the first
position when the command is
sent.
16
Unit
number
34
Teach Second
Position
Specifies the unit number as the
instance ID, and teaches the sec-
ond position when the command
is sent.
16
Unit
number
35
Start Zero
Reset
Specifies the unit number as the
instance ID, and starts the zero
reset operation when the com-
mand is sent.
06
Unit
number
50
Start Flashing
Specifies the unit number as the
instance ID, and starts flashing
when the command is sent.
16
Unit
number
53
Disable Zero
Reset
Specifies the unit number as the
instance ID, and disables the
zero reset operation when the
command is sent.
07
Unit
number
60
Stop Flashing
Specifies the unit number as the
instance ID, and stops flashing
when the command is sent.
07
Unit
number
63
Initialize Sensor
Settings
Specifies the unit number as the
instance ID, and resets all the
Sensor internal settings to the
default settings when the com-
mand is sent.
05
Unit
number
None
Reset
When the command is sent, all
the connected Sensors are reset
by turning the power OFF and
then ON again.
05
00
None
Summary of Contents for E3X-CIF11
Page 3: ...iv...
Page 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Page 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Page 107: ...96 CompoWay F Message Communications Section 4 5...
Page 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Page 133: ...122 DeviceNet Connection Settings Appendix C...
Page 135: ...124 DeviceNet Device Profile Appendix D...
Page 137: ...126 Revision History...