Overview of RS-422 Communication Unit
Section 4-1
4-1-3
Using RS-422 Communication Unit: Example
The following example is for executing Adjust Maximum Sensitivity for unit
number 1.
Adjust Maximum Sensitivity Command Block
The following CompoWay/F command block is executed.
Note When using the PMCR(260) instruction to send messages, the data from the
command block shown in bold is stored in word S onwards in the order shown
in the following diagram.
STX
Compo-
Way/F
node No.
Sub-
address
SID
MRC
SRC
Com-
mand
code
Related
informa-
tion
02 Hex
“02”
“00”
“0”
“30”
“05”
“30”
Unit No.
CS1W-SCB41 Serial Communications
Board using Port 2 (RS-422/485)
CS1 CPU
Unit
PMCR(260)
instruction
CompoWay/F
CompoWay/F
command
E3X-CIF11
CompoWay/F
Node 2
Unit 1 for which
maximum sensitivity
is being adjusted.
Fiber Sensors