64
Overview of RS-422 Communication Unit
Section 4-1
4-1
Overview of RS-422 Communication Unit
4-1-1
Introduction
The E3X-CIF11 for RS-422 communications is a Communication Unit that
uses RS-422 to communicate with one or more Fiber Optical Sensors through
Fiber Amplifier Units, including monitoring incident light levels, writing param-
eters, and controlling operation. Using CompoWay/F messages allows read-
ing and writing parameters.
4-1-2
RS-422 Communications Overview
Sending CompoWay/F commands from the CompoWay/F master to the Com-
munication Unit, which functions as a CompoWay/F slave, allows reading and
writing of parameters for the connected Sensors using CompoWay/F mes-
sage communications.
Serial Communication Unit
CPU Unit
Ladder program
PLC
CompoWay/F
message
RS-422
Fiber Sensors
E3X-CIF11 Fiber
Amplifier Unit for
RS-422
Power
supply
E3X-DA-N Digital Fiber
Amplifier Unit
Unit
1
Unit
2
Unit
13
PMCR (260)
instruction