95
CompoWay/F Message Communications
Section 4-5
Error Completion
Response
code
Error name
Cause
“1001”
Command too long
The command is too long.
“1002”
Command too short The command is too short.
“1101”
Area type error
The command code is wrong.
“1103”
Start address out-
of-range error
The unit number of an unconnected Sensor is
specified in the related information.
“2203”
Operation error
• A Sensor communications error has occurred.
• The Sensor response indicated a communica-
tions prohibited error.
• The Sensor did not respond.
• The Mobile Console is connected.
• The WRITE command for the second point/
position of Teach operations was sent before
executing the command for the first one.