34
Explicit Message Communications
Section 2-6
Read Hysteresis Width
Reads the hysteresis width of the Sensor for the unit number specified in the
instance ID. The data is given as a 3-digit hexadecimal value. Bits 14 and 15
are used to display the sensing setting.
Read Custom Flags
Reads whether the following settings for the Sensor of the unit number speci-
fied in the instance ID can be set or monitored from the sensor key switch.
Bit
Contents
00 to 11 Hysteresis Width
12
Always 0.
13
Always 0.
14
Sensing Setting:
0: Standard
2: Super long-distance
3: Super high-speed
15
Bit
Contents
00
Hold Setting:
0: Enable
1: Not displayed
2: Disable
01
02
Flashing Setting:
0: Enable
1: Not displayed
2: Disable
03
04
OFF-delay Timer Setting:
0: Enable
1: Not displayed
2: Disable
05
06
Sensing Setting:
0: Enable
1: Not displayed
2: Disable
07
08
Sensitivity Adjustment:
0: Enable
1: Disable
09
Teaching:
0: Enable
1: Disable
10
Display Contents:
0: Enable
1: Disable
11
Zero Reset:
0: Enable
1: Disable
12
Monitor Focus Range:
0: Enable
1: Not displayed
2: Disable
13
14
Display Orientation:
0: Enable
1: Not displayed
2: Disable
15
Summary of Contents for E3X-CIF11
Page 3: ...iv...
Page 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Page 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Page 107: ...96 CompoWay F Message Communications Section 4 5...
Page 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Page 133: ...122 DeviceNet Connection Settings Appendix C...
Page 135: ...124 DeviceNet Device Profile Appendix D...
Page 137: ...126 Revision History...