58
Resetting a Device
Section 3-6
3-6
Resetting a Device
This section describes how to reset a Safety Device.
3-6-1
Reset Types
The following three methods can be used to reset a Safety Device.
The Safety Device saves the following configuration information in nonvolatile
memory.
The information above is saved in nonvolatile memory in the device. It will not
be cleared by restarting the power supply. To clear the information (to return
to the default settings), select the
Reboot and reset configuration
or
Reboot
and reset configuration without
... Option when resetting.
Reset type
Description
Reboot
This is the same as turning the power OFF and ON.
Reboot and reset
configuration
All configuration information saved in the device's nonvolatile
memory will be returned to the default values and the device
will be restarted.
Reboot and reset
configuration with-
out specified items
All configuration information in the device's nonvolatile mem-
ory other than specified items will be returned to the default
values and the device will be restarted.
Type
Default
setting
Set when
Description
Node address
(software setting)
63
Node address is
changed.
The node address at startup
when software settings are
enabled.
Baud rate (soft-
ware setting)
125 Kbit/s
Baud rate is
changed
The baud rate at startup when
the software settings are
enabled (NE1A-series Con-
troller only).
TUNID (Target
Unique Node Iden-
tifier)
Not set
First time parame-
ters are down-
loaded.
The identifier of the local node
in the Safety Network consist-
ing of the network number
and node address.
Password
No pass-
word
Password is
changed.
The password for the device.
CFUNID (Configu-
ration Owning
UNID)
Not set
First time parame-
ters are down-
loaded.
The UNID of the configuration
source.
OCPUNID (Output
Connection Point
Owning UNID)
Not set
First time safety
communications
are started.
The UNID of the Safety Mas-
ter that opens a safety output
connection.
Summary of Contents for DeviceNet Safety NE1A-HDY01
Page 1: ...OPERATION MANUAL Cat No Z921 E1 01 DeviceNet Safety NE1A HDY01 Mobile Console ...
Page 2: ...DeviceNet Safety NE1A HDY01 Mobile Console Operation Manual Produced April 2009 ...
Page 3: ...iv ...
Page 9: ...x ...
Page 13: ...xiv ...
Page 23: ...xxiv Definition of Terms 8 ...
Page 47: ...24 Attaching the Hand Strap Section 1 10 ...
Page 59: ...36 Console Settings Section 2 2 ...
Page 90: ...67 Dimensions Section 4 4 4 4 Dimensions 4 4 1 Mobile Console 100 200 75 38 42 5 ...
Page 91: ...68 Dimensions Section 4 4 4 4 2 Charger 4 4 3 Battery Pack 70 40 120 38 72 20 ...