80
Timer (Block Model 205)
Section 6-11
6-11-1 Face Plates
The Timer indicates when a preset time has elapsed. A prediction SV can be
set for early notification.
1: Status Display
The Timer face plate does not provide a status display.
2: Y1 Value Display
A Numeral Display and Input object is used to display the value of tag ITEM
Y1 (ITEM 009).
A Control Flag is set to disable input.
3: SP Numerical Value Display and Input
A Numeral Display and Input object is used to display the value of tag ITEM
SP (ITEM 007). Touch this field to display a ten-key pad below it.
Data is written to the write address of tag ITEM SP (ITEM 007) using the
Before Writing Numeral/String macro.
$W2047=GETNUMVAL();
WRITECMEM([SP_W],$W2047,1);
RETURN(1);
The upper and lower limits are 0.0 to 3200.0.
4: PRS Numerical Value Display and Input
A Numeral Display and Input object is used to display the value of tag ITEM
PRS (ITEM 008). Touch this field to display a ten-key pad below it.
1
2
11
3
4
5
6
9
10
7
8
12