3 Configuration Software
3-14
CJ-series PROFINET IO Controller Unit Operation Manual for NJ-series CPU Unit (W511)
Additional Information
The FDT Monitoring view is hidden by default. After starting CX-ConfiguratorFDT, the window
will be displayed, by selecting the
View - FDT Monitoring
option from the main menu
The purpose of the FDT Monitoring view is troubleshooting in case problems occur with third party
DTMs. The contents of the window can be copied to the clipboard, to allow it to be pasted into
another document or into an E-mail. The messages themselves as well as the sequence of mes-
sages may hold additional clues in case of problems.
The format used in the FDT Monitoring view is:
Time:
<Time> Date: <Date> - <Information Type> <message>
The message may include the name of the DTM involved in the communication. The figure below
shows an example of an FDT Monitoring message sequence. This example sequence is generated
when opening a CJ1W-PNT21 PROFINET IO Controller Unit DTM.
Right-clicking in the Error Log view displays a context menu providing the options listed below.
Error Log View Context Menu
The FDT Standard defines four access levels and two attributes for FDT Container applications, which
can be used to restrict access to the program or certain features thereof for unauthorized personnel.
The actual use of the restrictions also depends on the application.
CX-ConfiguratorFDT implements the five levels as well as one of the attributes. These levels are listed
below.
•
Observer
•
Operator
•
Maintenance
•
Planning Engineer
•
Administrator
List Item
Description
Clear all entries
Clears the entire FDT Monitoring view
Copy to clipboard
Copies the entire contents of the FDT Monitoring view to the clipboard.
Hide
Hides the FDT Monitoring view
3-2-6
Access Control and User Management