3 Check and start operation
3-3 Start and stop procedures and basic operation
BU150R
45
3
Additional Information
When the power is restored after a power failure, the UPS is set by default to automatically
restart and supply power.
If you do not want to restart the connected devices, "Setting" switch 2 can be used to select
whether or not auto restart is performed, or turn OFF the "Power" switch of the connected
devices (See also "3-1-4 Setting Switch" ( P.35 ) ).
■
Operation when stopping
Note
Before stopping the commercial power to the unit, turn OFF the "Power"
switch of the unit.
When the AC Input Plugs are disconnected from a wall outlet (commercial power
source), the unit enters Battery Mode. Before disconnection, turn off the
“
Power
”
.If you
frequently use the unit in Battery Mode, the battery life may be significantly shortened.
Press and release the "Power" switch of the UPS, and then the "Power" switch turns OFF.
The power output from the UPS stops at the same time.
Additional Information
Even if you turn off the "Power" switch, if AC is supplied from commercial power, the
battery is automatically charged.