![background image](http://html1.mh-extra.com/html/omron/2d-code-reader/2d-code-reader_user-manual_741416072.webp)
71
V400-F050/250/350
User’s Manual
Sec
tion 5
RS-
232
C Communica
tion
Section 5
Communicating with PC and Programmable Controller
VR
CB
CU
Function... Checks the version information.
* The above value is given as an example.
Function... Backs up the setting data to the PC.
After “READY” is output, the main unit switches to XMODEM
communication automatically, and outputs
when communication
is completed successfully.
Function... Loads the setting data from the PC.
After “READY” is output, the controller switches to XMODEM
communication automatically, and outputs
when communication
is completed successfully.
Input
V R
Output
1
.
0
0
Input
Backup source
C
B
Specify the data to be backed up.
Backup source
Details
AL
All data
SY
System data
BK
All reading condition data
B0 to 9
Corresponding reading condition data
00 to 27
Corresponding image No.
Output
R
E
A
D
Y
O K
Input
Upload source
C
U
Specify the data to be uploaded from the PC.
Upload source
Details
AL
All data
SY
System data
BK
All reading condition data
B0 to 9
Corresponding reading condition data
00 to 27
Corresponding image No.
Output
R
E
A
D
Y
O K
Summary of Contents for 2D CODE READER
Page 1: ...USER S MANUAL 2D Code Reader V400 F050 250 350 Cat No Z242 E1 03...
Page 13: ...12 Introduction Contents V400 F050 250 350 User s Manual Introduction MEMO...
Page 85: ...84 Section 6 Troubleshooting V400 F050 250 350 User s Manual Section 6 Troubleshooting MEMO...