Appendix
CS/CJ-series PLC Settings
Change the settings in the PLC Setup to those shown below using the CX-Programmer
and then transfer the settings to the CPU Unit of the PLC.
Communications Settings: Select the Custom Option and then set the baud rate to
9,600 and the format to “8,1,N”.
Mode: RS-232C
Start Code: Select Disable Option.
End Code: Select the Set End Code Option and set “000D”.